Material:304 stainless steel
Qualification Certification:ISO13485/ISO9001/ISO14001/ISO45001
Minimum Order Quantity:1
Sample Request:Each product can apply for a
 
Product Introduction

A comprehensive portfolio covers various jaw styles, shaft diameters and working lengths: single‑action straight jaw, right‑angle angled jaw and double‑action jaw are available. Diameter options include Φ5 mm and Φ10 mm; shaft lengths include standard 330 mm and extended 400 mm / 410 mm variants, compatible with small, medium and large titanium clips for diverse laparoscopic procedures across general surgery, gynecology and urology.
 
  • Ф5 Ф10

  • highmeda

Availability:
Quantity:

Titanium Clip, Clip Applicator

Model No.

Type of clamp head

Specification

299.1.05 Titanium Clip Applicator (Single Action/Small Size) Ф5×330
299.2.10 Titanium Clip Applicator (Single Action/Middle Size) Ф10×330
299.3.10 Titanium Clip Applicator (Single Action/Large Size) Ф10×330
299.1.5L Titanium Clip Applicator (Single Action/Small Size) Ф5×400
299.1.5W Titanium Clip Applicator (Small size) Ф5×410
299.4.10 Titanium Clip Applicator (Right Angle) Ф10×330
299.4.10L Titanium Clip Applicator (Right Angle) Ф10×400
299.5.10 Titanium Clip Applicator (Double Action) Ф10×330
Quality Certification ISO13485/ISO9001/ISO14001/ISO45001
Type of Usage Reusable
Shelf Life 5 Years
Warranty 1 Year

The titanium clip applicator is a precision delivery and release instrument specifically designed for modern surgical procedures. Its core mission is to accurately, efficiently, and safely deliver titanium clips to target vessels or tissues, ensuring reliable closure. It is not merely a simple clamping device but an extension of the surgeon's hand, enabling precise operations within confined spaces.

松夹钳

Product Structure and Features:

1. Superior Ergonomics Design

- Comfortable Grip: The handle incorporates finger rings and anti-slip textures that conform to hand mechanics, providing a secure and comfortable grasp, effectively reducing hand fatigue during prolonged surgeries.

- Lightweight Construction: Utilizing high-strength aviation-grade aluminum or composite polymer materials, the instrument maintains structural integrity while significantly reducing weight, enhancing maneuverability and reducing operator fatigue.

- Optimized Force Transmission: A precision internal transmission mechanism ensures smooth transfer of clamping force to the jaws, achieving precise "point-and-shoot" control.

2. Precision Jaw and Transmission Mechanism

- Low-profile Jaw Design: The slender jaws minimize visual obstruction, particularly suitable for laparoscopic and other minimally invasive procedures, providing optimal surgical visibility.

- Reliable Clamping and Deployment: The internal mechanical structure ensures stable deployment and uniform closure of titanium clips during each firing, preventing "jumping" or "twisting" phenomena.

- Clear Firing Feedback: Audible "click" sounds and tactile feedback during operation allow surgeons to confirm successful clip release without direct visual confirmation, enhancing operational confidence.

3. Flexible Maneuverability

- Multiple Jaw Configurations: Available in straight, left-curved, and right-curved variants to accommodate diverse anatomical requirements.


Core Advantages:

- High Reliability: Titanium clips provide stable mechanical closure force with minimal risk of detachment.

- Immediate Effectiveness: Effective hemostasis or occlusion is achieved instantly upon clip closure.

- Excellent Tissue Compatibility: Titanium metal induces minimal tissue rejection or inflammatory response.

- Simplified Operation: Streamlines ligation in deep or narrow spaces, particularly suitable for laparoscopic minimally invasive surgeries.

- Precise Positioning: Enables accurate placement of titanium clips in complex anatomical structures.

- Stable Deployment: Prevents slippage, tilting, or incomplete closure during deployment.

- Enhanced Surgical Fluidity: Reduces procedural interruptions caused by instrument issues, shortening overall surgical time.


Highmeda reusable titanium clip applicator is constructed from medical-grade 304 stainless steel, the core guarantee of its consistent quality. The material features excellent corrosion resistance. Its finely polished surface facilitates cleaning of blood and tissue residue. It supports repeated autoclave sterilization, resisting rust and deformation after many sterilization cycles. The transmission mechanism stays smooth for extended service life. Compared with disposable clip appliers, this reusable model effectively cuts long-term consumable expenditure for hospitals, minimally invasive centers and distributors. The ergonomic anti-slip finger-ring handle reduces fatigue during long operations. Precision internal linkage delivers clear tactile and audible feedback when the clip is fired, helping surgeons confirm successful clip placement without visual guesswork.

Anatomical conditions vary greatly: vessel size, surgical depth, tissue space and patient body habitus differ case by case. That is why our titanium clip applicator portfolio covers a full range of jaw styles, shaft diameters and working lengths, compatible with small, medium and large titanium clips for versatile clinical needs.

Three jaw types are available: single-action straight jaw, right-angle angled jaw and double-action jaw. Single-action straight jaw is the classic universal option with low profile, less visual obstruction and simple operation for most routine cases. Right-angle angled jaw reaches deep, offset anatomical sites hidden by organs, ideal for critical areas such as the cystic triangle and deep pelvic space. Double-action jaw opens and closes symmetrically, offering balanced grip and superior stability for high-tension tissue bundles.

Two mainstream shaft diameters: Φ5 mm and Φ10 mm, matching corresponding trocar channels. Working lengths include standard 330 mm and extended 400 mm / 410 mm versions. Standard length fits routine procedures on average patients; extended shafts are engineered for deep dissection, obese patients and retroperitoneal operations, solving the problem of insufficient reach.

Surgeons can select the right model according to clinical demands: Φ5 mm small applicators for fine, small vessels; Φ10 mm medium & large applicators for bigger vascular pedicles; standard shafts for superficial access, extended or angled jaws for deep and complex procedures.

It is widely used for laparoscopic cholecystectomy, gastrointestinal surgery, hernia repair, gynecological and urological minimally invasive procedures, to ligate arteries, veins, bile ducts and lymphatic ducts. Titanium clips are biologically inert with minimal tissue reaction and limited imaging artifacts, safe for permanent implantation.